Exploratory evidence · subjective-pilot-v1

25-dome subjective pilot

One rater scored 25 dome assemblies in three fixed-order sessions. The fixed 5×5 grid held 25 separate, nominally matched OEM Topre assemblies; each used an OEM Topre housing, black Topre slider, and OEM Topre conical spring. Dome identity, fixed position, and unit-to-unit assembly variation were confounded, and continuity of each assembly across sessions was not separately recorded. Weight and tactility sharpness used panel-relative 1–10 scales.

Read this first. The effective sample is 25 domes, not 75. These results describe associations inside this selected panel. They are not causal effects, calibrated perceptual units, population norms, or a tactile on/off classifier.

Strongest rank associations

Perceived weight

Mechanical metricSpearman ρ
Collapse force0.952
Ramp0.897
Pre-collapse work0.839
Drop0.822
Drop rate0.818

Tactility sharpness

Mechanical metricSpearman ρ
Drop0.930
Steepest 0.10 mm drop0.915
Drop rate0.906
Snap %0.903
Normalized drop rate0.846

Collapse force led the perceived-weight ranking (ρ = 0.952). The force-drop family led tactility-sharpness: Drop ρ = 0.930. These correlated metric families overlap strongly, so this pilot does not assign independent causal contributions.

Limits

Files

Methods75 session-by-dome rows · 150 numeric ratings25 dome meansExplicit 5x5 mappingAnalysis resultsProvenance

Return to Force Curve Bench